3. X-SEL-J/K/P/Q/JX/KX/PX/QX
32
3.3.6 X-SEL I/O Port Numbers
The standard I/O port numbers of the X-SEL are listed below.
The port numbers and function assignments of the X-SEL can be changed using I/O parameters.
(For details, refer to “Operation Manual for X-SEL Controller.”)
Port No.
Function
Port No.
Function
000
Program start
300
Alarm output
001
General-purpose input
301
Ready output
002
General-purpose input
302
Emergency stop output
003
General-purpose input
303
General-purpose output
004
General-purpose input
304
General-purpose output
005
General-purpose input
305
General-purpose output
006
General-purpose input
306
General-purpose output
007
Program specification (PRG No. 1)
307
General-purpose output
008
Program specification (PRG No. 2)
308
General-purpose output
009
Program specification (PRG No. 4)
309
General-purpose output
010
Program specification (PRG No. 8)
310
General-purpose output
011
Program specification (PRG No. 10)
311 General-purpose
output
012
Program specification (PRG No. 20)
312 General-purpose
output
013
Program specification (PRG No. 40)
313 General-purpose
output
014
General-purpose input
314
General-purpose output
015
General-purpose input
315
General-purpose output
Input
Output
(Note)
The above functions are based on the factory-set default parameter settings.