4. XSEL-R/S/RX/SX/RXD/SXD
45
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
10
Standard I/O Error Monitoring
(I/O1)
1
0 to 5
0
0:No Monitoring (Not to use I/O board)
1:Monitoring
2:Monitoring (Not to monitor 24V I/O power
related error)
3:Monitoring (To monitor only 24V I/O
power related error)
14
No. of Network I/F Module 1
Remote Input Ports
0
0 to 256
0
8 port unit
15
No. of Network I/F Module 1
Remote Output Ports
0
0 to 256
0
8 port unit
16
Input Port Start No. in Network I/F
Module Fix-Allocated
-1
-1 to 599
-1
0+ (Multiples of 8)
[Ineffective when -1 is selected]
17
Output Port Start No. in Network I/F
Module Fix-Allocated
-1
-1 to 599
-1
300+ (Multiples of 8)
[Ineffective when -1 is selected]
18
Network I/F Module 1
Error Monitoring
1
0 to 5
0
0:No Monitoring
(Not to use Network I/F Module 1)
1:Monitoring
120 Network attribute 1
640001H
0 to
FFFFFFFFH
Optional
Bits 16 to 23:
Value of Link Timeout at initializing
(Example) Default 64H = 10sec
121 Network attribute 2
0H
0 to
FFFFFFFFH
Optional
Bits 8 to 15:
Input port data selected at Network I/F
Module 2 link error
0:Input port data clear
1:Input port data retained
225 Network I/F Module Control
3*
00H to 37H
30
Bits 0 to 3:
Network I/F Module 1 type
0:Not Mounted
6:EtherCAT
7:EtherNet/IP
Bits 4 to 7:
Network I/F Module 2 type
0:Not Mounted
1:CC-Link
2:DeviceNet
3:PROFIBUS
231
No. of Network I/F Module 2
Remote Input Ports
0
0 to 256
16
8 port unit
232
No. of Network I/F Module 2
Remote Output Ports
0
0 to 256
16
8 port unit
233
Extension Input Port Start No.
at Network I/F Module 2 Fixed
Assignment
-1
-1 to 299
1000 to 3999
0
0+ (Multiples of 8)
or
1000+ (Multiples of 8)
[Ineffective when -1 is selected]
234
Extension Output Port Start No.
at Network I/F Module 2 Fixed
Assignment
-1
-1
300 to 599
4000 to 6999
300
300+ (Multiples of 8)
or
4000+ (Multiples of 8)
[Ineffective when -1 is selected]
235
Network I/F Module 2
Error Monitoring
1
0 to 5
1
0:No Monitoring (Not to monitor condition
of link to PLC (master))
1:Monitoring
237
Network I/F Module 2
Node Address
0
0 to 125
Optional PROFIBUS node address range: 0 to 125