IAI America E-Con User Manual
Page 91
7.
ASEL, PSEL, SSEL
83
ASEL, PSEL and SSEL Network I/O Parameter List
No. Parameter
name
Factory-set
value
Input range
Remarks
1
Input/output port assignment
type
0 0
~
20
0: Fixed assignment
1: Automatic assignment
14
Network I/F module: Remote
input ports used
64
0 ~ 256
Multiple of 8
15
Network I/F module: Remote
output ports used
64
0 ~ 256
Multiple of 8
16
Network I/F module fixed
assignment: Initial input port
number
0
-1 ~ 599
0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)
17
Network I/F module fixed
assignment: Initial output port
number
300
-1 ~ 599
300 + (multiple of 8) (The parameter is invalid if a
negative value is set.)
18
Network I/F module: Error
monitor
1
0 ~ 5
0: Not monitored 1: Monitored
* If a network link error continues for the
network link error check timer period or
longer,
a system error will occur. (Refer to I/O
parameter No. 120.)
* Some exceptions apply.
120
Network attribute 1
1
H
0
H
~
FFFFFFFF
H
Bits 0 to 3: Reserved by system
Bits 4 to 11: Network link error check timer
period (set in units of 10 msec)
Valid only when I/O parameter No. 18 = 1.
(Example) If the set value is 05H (bits 4 to 11),
the timer period becomes 50 ms
(10 ms x 5). If the set value is 0H, a
system error occurs immediately
due to a network link error.
225
Network I/F module: Control
3
H
For
reference
only
Bits 0 to 3: Network I/F module type
(0: Not installed, 1: CC-Link module,
2: DeviceNet module, 3: ProfiBus module)
226
Network I/F module:
Communication attribute 1
1
0 ~ 999
Node address of network I/F module
* If a ProfiBus module is used: 0 to 125
227
Network I/F module:
Communication attribute 2
0
H
0
H
~
FFFFFFFF
H
Bits 0 to 3: Baud rate type of network I/F
module
* If a ProfiBus module is used, the baud rate is
automatically set according to the
corresponding setting on the master side and
thus need not be set.