4 setting example – IAI America E-Con User Manual

Page 52

background image

4. XSEL-R/S/RX/SX/RXD/SXD

44

4.4 Setting example

(1) Example for when using only PROFIBUS

It is how to establish the setting when using PROFIBUS to 16 points of each input and output from the top of the
standard I/O ports, and no other I/O port (for I/O board, etc.) is to be used.

Standard Input Port No.0 to 15
Standard Output Port No.300 to 315
(PROFIBUS board)

Not Applicable (I/O board)

xI/O Parameters

No.

Parameter name

Default

(Reference)

Input Range

Unit

Remarks

1

I/O Port Allocation Type

1

0 to 1

0

0:Fixed Allocation
1:Automatic Allocation
xReference 1 Priority of I/O Port Assignment when

automatically assigned

Port Number

(No.0 to 299/No.300 to 599)

1) Network I/F Module 1
2) I/O slot 1 (I/O1) Mounting board
3) I/O slot 2 (I/O2) Mounting board
* I/O slot 1 (I/O1) Assigned for the

continuously mounted range from
mounting board

xReference 2 Priority of extension I/O ports at

automatic assignment

Port Number

(No.1000 to 3999/No.4000 to 6999)

1) Network I/F Module 2
2) Expansion I/O unit
3) IA Net

2

Standard I/O Fix-Allocated
Input Port Start No.

0

-1 to 599

-1

0+ (Multiples of 8)
[Ineffective when -1 is selected]

3

Standard I/O Fix-Allocated
Output Port Start No.

300

-1 to 599

-1

300+ (Multiples of 8)
[Ineffective when -1 is selected]