3. X-SEL-J/K/P/Q/JX/KX/PX/QX

34

2)

Address assignment in the master station
When setting the configuration in 1) using a configurator, the numbers of inputs and outputs of the X-SEL set
for slave station 2 must be determined. (Here, it is assumed that the number of occupiable slave stations is
set to 16 words in the master station.)

3)

When the X-SEL conforming to the configuration example shown in 1) has total eight words of input and
output points (128 points), respectively.

The X-SEL’s I/O parameters are set as follows.

No.

Parameter name

Input range

Settings

Remarks

1

Input/output port assignment
type

0 ~ 20

1

0: Fixed assignment
1: Automatic assignment (Priority: Slot 1 ~)
* Ports are assigned automatically only for the

contiguous slots in use, starting from slot 1 =
For safety reasons.

2

Standard I/O fixed assignment:
Initial input port number (I/O1)

-1 ~ 599

000

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

3

Standard I/O fixed assignment:
Initial output port number (I/O1)

-1 ~ 599

300

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

4

Expansion I/O1 fixed
assignment: Initial input port
number (I/O2)

-1 ~ 599

-1

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)
(Slot next to standard I/O)

5

Expansion I/O1 fixed
assignment: Initial output port
number (I/O2)

-1 ~ 599

-1

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

6

Expansion I/O2 fixed
assignment: Initial input port
number (I/O3)

-1 ~ 599

-1

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

7

Expansion I/O2 fixed
assignment: Initial output port
number (I/O3)

-1 ~ 599

-1

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

8

Expansion I/O3 fixed
assignment: Initial input port
number (I/O4)

-1 ~ 599

-1

0 + (multiple of 8) (The parameter is invalid if a
negative value is set.)

9

Expansion I/O3 fixed
assignment: Initial output port
number (I/O4)

-1 ~ 599

-1

300 + (multiple of 8) (The parameter is invalid if
a negative value is set.)

10 Standard I/O error monitor

0 ~ 5

2

0: Not monitored

11 Expansion I/O1 error monitor

0 ~ 5

0

1: Monitored

12

Expansion I/O2 error monitor

0 ~ 5

0

2: Monitored (only 24-V I/O power errors are

not monitored)

(Main application version 0.55 or later)

13

Expansion I/O3 error monitor

0 ~ 5

0

3: Monitored (only 24-V I/O power errors are

not monitored).

(Main application version 0.55 or later)

14

Network I/F card remote input
ports used

0 ~ 256

64

Multiple of 16

15

Network I/F card remote output
ports used

0 ~ 256

64

Multiple of 16