IAI America ACON-SE User Manual
Page 84
![background image](/manuals/350310/84/background.png)
74
4. Description of Operating Functions
(3) Notes on push & hold operation
If the start signal is input with a position number using relative coordinates (push specification) selected/entered
while the actuator is moving in the push & hold mode, the actuator will move to the position corresponding to the
position at the time of start input plus the relative movement. Therefore, the end position will become
indeterminate.
Example) If the start signal for movement to position 2 is input while the actuator is moving to position 1 in the
push & hold mode, the actuator will move to the position 10 mm from where it was when the input
signal was input.
Position command
Positioning start
Position complete (PEND)
Completed position
Moving (MOVE)
Actuator movement
Speed
Position 1
Position 2
Position 2
Distance
Position 2
Position 1
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)