18
6SHFL¿FDWLRQV
2. Specifications
2.1 Basic
Specifications
Specification item
Description
Model ACON-SE
Number of controlled axes
1 axis per unit
Power-supply voltage
24 VDC
r 10%
Standard specification/Support high
acceleration/deceleration
Support power-saving
Actuator Motor
type
Rated [A]
Maximum (Note 2)
Rated [A]
Maximum (Note 2)
10 W
1.3
4.4
1.3
2.5
20 W [Model code: 20]
1.3
4.4
1.3
2.5
30 W
1.3
4.0
1.3
2.2
RCA/
RCA2
20 W [Model code: 20S]
For RA3, RA4 and TA5
types only
1.7 5.1 1.7 3.4
2 W
0.8
4.6
5 W
1.0
6.4
Motor power
supply
capacity
(Note 1)
RCL
10 W
1.3
6.4
Heat output
8.4 W
RCA 800
Pulse/rev
RCA2-
N
1048 Pulse/rev
RCA2
Other than RCA2-
N 800 Pulse/rev
RA1L/ SA1L/ SA4L/ SM4L 715 Pulse/rev
RA2L/ SA2L/ SA5L/ SM5L 855 Pulse/rev
Encoder
resolution
RCL
RA3L/ SA3L/ SA6L/ SM6L 1145 Pulse/rev
Positioning command
Position no. specification, numerical specification, simple direct value/position no.
specification
Backup memory
Position table data and parameters are saved in nonvolatile memory.
Serial EEPROM can be rewritten 100,000 times.
Position number
Maximum 64 points
LED indicator
SV (green): Servo ON state, ALM (red): Alarm state
Serial communication
RS485 1 channel
Communication protocol
Modbus/RTU, Modbus/ASCII
Encoder interface
Incremental specification conforming to EIA RS-422A/423A
Forced release of electromagnetic brake
24 V applied to BK terminal on terminal block
Actuator cable: 20 m or less
Cable length
Communication cable: Total cable length 100 m or less
Dielectric strength
500 VDC, 10 m
:
Surrounding air temperature
0 to 40
qC
Surrounding humidity
85%RH or less (non-condensing)
Surrounding environment
Not subject to corrosive gases
Surrounding storage temperature
-10 to 65
qC
Surrounding storage humidity
90%RH or less (non-condensing)
Environment
Vibration resistance
10 to 57 Hz in XYZ directions, Pulsating amplitude: 0.035mm (continuous), 0.075mm
(intermittent)
Protection class
Air cooling without blower (IP20)
Weight
128 g or less
External dimensions
35 W
u 120 H u 68 D mm
(Note 1) Rush current of 5 to 12 times the rated current is conducted for approximately 1 to 2 msec after turning the power on. Note
that the rush current value varies depending on the impedance of the power line.
(Note 2) The maximum current is conducted at the servo motor exciting phase detection performed in the first servo on processing
after turning the power on (normally: approximately 1 to 2 seconds, maximum: 10 seconds)
)RUWKH'&SRZHUVXSSO\RI9VHOHFWWKH³SHDNORDG´VSHFLILFDWLRQRUDSRZHUVXSSO\KDYLQJVXIILFLHQWDOORZDQFH,QSDUWicular, pay