CognitiveTPG DLXi User Manual
Page 318

T R O U B L E S H O O T I N G
Numeric values do not increment properly in response to the
ADJUST command.
Cause: The numeric value you wish to adjust has more digits than
the parameter specified in the
command.
• Cure: Pad the
parameter with leading zeros as
required.
Cause: You are trying to adjust a numeric value to a number with
more digits than the original value.
• Cure: Pad the original value with leading zeros as required.
Cause: You are using a
• Cure: This is acceptable, but remember:
will only
increment the adjusted numeric value when the printer feeds a
label. Duplicate labels printed side-by-side will always be identical.
Cause: You are trying to increment numeric data that does not
appear at the end of a command line.
• Cure: This may be acceptable, but the
only increment numeric data. If alpha characters follow the
numeric data, you must follow the
parameter with enough
zeros to pad the increment value away from the alpha characters.
Bar code or string positioning is incorrect.
Cause: A required space was left out or an extra space was inserted
somewhere in the
command, causing the printer
to interpret the parameters incorrectly.
• Cure: Use blank spaces as shown in the command descriptions.
Ultra Font or TEXT font positioning is incorrect.
Cause: The label format has a
not accounted for.
Revision F, January 2012, CognitiveTPG
309