Variable feed_config – CognitiveTPG DLXi User Manual
Page 211

P R I N T E R S E T U P
VARIABLE FEED_CONFIG
Function
This command is used to determine what the
printer should do when coming online both at power
up and after the print head has been closed. The
printer is able to feed to the next label, perform an
index calibration, measure the label length or take
no action.
Explicit Form
VARIABLE FEED_CONFIG P,D/?
Parameters
P
D
?
Action to be performed at power up
Action to be performed when the print
head is closed.
Returns the current setting status.
Possible values for P and D:
N – Take no action. This is the default
setting.
F – Feed to the next label.
C – Perform an index calibration.
L – Measure label length.
Comments
The power up action can be different than the head
close action, or it can be the same. When using this
command to perform an index calibration the
VARIABLE MEASURE_LABEL command should
also be used since it is possible for the labels to be
measured any time an index calibration is
performed.
When using this command, send it to the printer
with VARIABLE WRITE in a non-printing label
format. Do not use this command in stored label
formats.
See also
VARIABLE MEASURE_LABEL, VARIABLE
202
Revision F, January 2012, CognitiveTPG