U S I N G V A R I A B L E C O M M A N D S
The following label format disables Blazer emulation mode and
returns the printer to normal operation:
! 0 0 0 0
VARIABLE MODE 0
VARIABLE WRITE
END
There are many aspects to printer compatibility. You may want to
request a copy of Technical Bulletin 10-00-0131, which covers
Blazer/Blaster compatibility in detail. Contact our Technical Support
Organization for more information.
Setting DT or TT Print Method
Thermal transfer Barcode Blasters can print in direct thermal or
thermal transfer mode, but you must set the printer for the correct
media type. After loading the appropriate media, set the printer for the
correct media type using the VARIABLE PRINT_MODE command.
Use one of the following label formats to set the print method:
For thermal transfer printing:
! 0 0 0 0
VARIABLE PRINT_MODE TT
VARIABLE WRITE
END
For direct thermal printing:
! 0 0 0 0
VARIABLE PRINT_MODE DT
VARIABLE WRITE
END