Recalling a background from memory, Comm./ip configuration menu, Viewing serial port and ip settings – Extron Electronics MGP 462xi Series User Manual
Page 40: Recalling a background from memory -18, Comm./ip configuration menu, Ont panel (see, Comm./ip configuration, Menu, Preliminar y, Operation, cont’d
Operation, cont’d
MGP Series • Operation
3-18
PRELIMINAR
Y
Recalling a background from memory
To recall an image from memory for use as a background,
1
.
Press Menu repeatedly until the Background Capture screen is displayed.
2
.
Press Next repeatedly until the Recall Background from Memory submenu
screen is displayed.
3
.
Rotate either Adjust knob to select one of background image files to recall for
use as the output background.
To perform no action, press the Menu button.
4
.
Press the Next button to recall the image. The LCD screen displays the
message “Recalling” while the image is being recalled, then “Recalled” after
the recall is complete.
Comm./IP Configuration menu
Use the Comm./IP Configuration menu to view and edit the serial communication
port configuration and the MGP’s IP addresses. The Comm./IP Configuration
menu consists of two levels: view and edit.
Viewing serial port and IP settings
When you first reach the Comm./IP Configuration menu, you are on view level;
that is, all the screens that you cycle through by pressing Next show the current
settings. You cannot make changes from them. To view the serial port and IP
settings,
1
.
Press Menu repeatedly until the Comm./IP Configuration menu is displayed.
2
.
Press Next repeatedly to cycle through the screens displaying the current
settings for the serial port, MAC address, DHCP mode, IP address, Gateway
address, and Subnet mask.
3
.
Press Menu to return to the Comm./IP Configuration screen.
Making changes to the serial port and IP configuration
To make changes to the serial port configuration, IP address, DHCP mode, Gateway
address, and/or Subnet mask, you must access the edit level screens as follows:
1
.
With any Comm./IP Configuration menu view-level screen displayed,
press the Enter button and hold it until the Serial Config screen appears
(approximately 2 seconds).
2
.
Press Next repeatedly to cycle through the edit level screens.
3
.
To enter or change information on each screen, rotate the horizontal Adjust
knob (
[
) to move the angle brackets to the desired setting. Rotate the
vertical Adjust knob (
{
) to adjust the setting.
4
.
When finished editing the settings for the selected item, either press Next to
go to the editing screen for the next item, or press Menu to exit serial/IP edit
mode and go to the next menu (Advanced Configuration).
Screens are provided for editing the following parameters:
•
Serial Config:
Configure the serial port by switching between RS-232 and
RS-422, and selecting the baud rate.
•
Set DHCP Mode:
Set DHCP to On or Off.
N