Output type submenu, Sync polarity submenu, Output type submenu -13 sync polarity submenu -13 – Extron Electronics MGP 462xi Series User Manual
Page 35: Preliminar y

3-13
MGP Series • Operation
PRELIMINAR
Y
Resolution
Refresh Rates
24 Hz
50 Hz
59.94 Hz 60 Hz
72 Hz
96 Hz
100 Hz
120 Hz
1920 x 1200
X
X
480p
X
X
576p
X
720p
X
X
X
1080i
X
X
X
1080p
X
X
X
X
1080p Sharp
1
X
DVI BCKGD
2
RATE Resolution and clock of the incoming background input
1
An HDTV 1080p rate specifically tailored to Sharp
®
Professional displays (such as
the G655u).
2
When DVI BCKGD is selected as the output resolution/rate, the MGP uses
the incoming DVI background input resolution and clock as the output rate.
The sync type and polarity options are available for the RGB output while the
background timings are used. If available, the output of the MGP is locked to the
DVI background rate until you select a different resolution or disconnect the DVI
background input.
By default, the resolution provided in the Extended Display Identification
Data (EDID) is the last selected factory rate. To manually set the resolution
information provided in the EDID data, see the Set EDID information SIS
command on page 4-10.
Output Type submenu
Rotate either the horizontal Adjust (
[
) or the vertical Adjust ({) knob to select
the output signal type required by the display device. Available signal types are
RGBHV, RGSb, RGBS, YUV bi-level and YUV tri-level. The default is RGBHV.
Sync Polarity submenu
The display device may require a particular combination of horizontal (H) and
vertical (V) sync signal polarities. Rotate either the horizontal Adjust (
[
) or the
vertical Adjust ({) knob to select the sync polarity. The options are H-V-, H+V-,
H-V+, H+V+, or NA (appears when YUV Bi-lvl or YUV TriLvl is selected). The
default is H-V-.