beautypg.com

Extron Electronics CCR-2BLB AAP User Manual

Ccr-4blb aap and ccr-2blb aap wiring guide, About the contact closure control panels, Connectors

background image

68-1354-01

Rev. A

02 07

PO

WE

R

LA

N

12V

5A

INP

UT

2

1

3

4

5

6

7

8

1

2

3

4

Extron
IPL T CR48

Ethernet Control
Interface

Projector

Screen
Control

Projector
Lift
Control

Laptop

TCP/IP

Network

Extron
CCR-4BLB AAP
Controller Module

Contact closure outputs
Inputs to control LEDs
Requires 12V/0.1A power for LED illumination
Power not required for contact closure only operation

SCREE

N

DO

WN

SCREE

N

UP

PR

OJ

DO

WN

PR

OJ

UP

Figure 4 — A typical setup for the CCR-4BLB AAP

Extron Electronics, USA

1230 South Lewis Street

Anaheim, CA 92805

800.633.9876 714.491.1500

FAX 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C

3821 AH Amersfoort, The Netherlands

+800.3987.6673 +31.33.453.4040

FAX +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Rd. #04-01

PM Industrial Bldg., Singapore 368363

+800.7339.8766 +65.6383.4400

FAX +65.6383.4664

Extron Electronics, Japan

Kyodo Building, 16 Ichibancho

Chiyoda-ku, Tokyo 102-0082

Japan

+81.3.3511.7655 FAX +81.3.3511.7656

www.extron.com

Extron
VSW 2VGA A

VGA Switcher

Projector

Sound System

Local Monitor

FR

ON

T P

AN

EL

LO

CK

OU

T

RS

-23

2

PR

OT

EC

T

CH

1

CH

2

AP

A 7

54

AU

DIO

PO

WE

R A

MP

LIF

IER

CL

IP

NO

RM

SIG

NA

L

Extron
CCR-2BLB AAP
Controller Module

Contact closure outputs
Requires 12V/0.1A Power for LED illumination
Power not required for contact closure only operation

VSW 2V

GA

A

INP

UT

1

2

1

INP

UT

2

Laptop

PC

LAPT

OP

PC

Figure 5— A typical setup for the CCR-2BLB AAP

CCR-4BLB AAP and CCR-2BLB AAP

Wiring Guide

About the Contact Closure Control Panels

The Extron CCR-4BLB AAP and CCR-2BLB AAP are double

spaced, control module architectural adapter plates (AAPs). As

remote modules, these AAPs can control almost any contact

closure controllable device such as Extron switchers and

projection screens. They fit into all Extron AAP spaces and

include options for two (CCR-2BLB) or four (CCR-4BLB) backlit

buttons.
Externally powered, backlit buttons indicate system status by

lighting high amber when the input is closed or low amber

when the input is open. See “Inputs” at right.
N

The CCR AAPs must receive power for their illuminating

buttons to light, but power is not required for contact
closure usage.

Extron’s Button Label Generator software, available for

download at www.extron.com, creates customized labels with

text or icons that fit into the button keycap.

Connectors

Power (12V)

The 2-pole connector is for a power connection

to the control panel that lights up the buttons to low amber.

Buttons light to high amber only when the Input pins are driven

low. See “Inputs” at right.

Inputs

Each button has an input pin for controlling button

illumination. Driving an input pin low (shorting it to ground)

causes the the corresponding button to light high amber. Each

input can handle 18V and sink 1.5mA maximum.
Outputs

Each button has corresponding output pins that

are normally open (high). When the button is pressed the

pins close (go low).

Input

1 2 G 3 4 G

Output

1 2 G 3 4 G

Power

12V G

Figure 1 — CCR-4BLB AAP connectors

Input

1

2

G

Output

1

2

G

Power

12V G

Figure 2 — CCR-2BLB AAP connectors

In

+5v

1K

Ground

Input

Output

Out

Ground

Figure 3 — Schematics for CCR AAP input and ouput