7 go –settings menu (menu 7) – R&M Materials Handling HOIST MONITORS User Manual
Page 89

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
89/105
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
16.7 GO –settings menu (Menu 7)
Values are equal to the ones in Menu 1 and/or Menu 2 (monitoring items). After a General
Overhaul has been performed, these parameter have to be reset to the original value (zero)
unless otherwise indicated
7
GO-setup
GO-settings menu. Accessible with password level 7
Param. Name
Value
Description
7-1
Cycles
“nnnnn”
Number of hoisting cycles
7-2
MFI1 RT
“nnnn” h
MFI1 running time
7-3
MFI1 ST
“nnnnn”
MFI1 starts
7-4
MFI2 RT
“nnnn” h
MFI2 running time
7-5
MFI2 ST
“nnnnn”
MFI2 starts
7-6
RT slow
“nnnn” h
Run-time in slow speed
7-7
RT fast
“nnnn” h
Run-time in fast speed
7-8
No. OT
“nnnnn”
Number of hoist motor overtemperature incidents. Reset when the hoisting motor has been replaced
7-9
No. OL
“nnnnn”
Number of hoist overload incidents
7-10
E-stops
“nnnnn”
Number of emergency stops
7-11
ST up
“nnnnn”
Number of starts in up direction
7-12
ST down
“nnnnn”
Number of starts in down direction
7-13
ST fast
“nnnnn”
Number of starts to fast speed (two step control only)
7-14
Max ED
“nn” %
Maximum ED value
7-15
Over ED
“nnnnn”
Number of cases where ED value has exceeded the rated ED value
7-16
SRT3
“nnnnn”
Load sum with hoist running time, third power
7-17
SRT8
“nnnnn”
Load sum with hoist running time, eight power
7-18
SL1
“nnnnn”
Load sum with hoist cycles, the first power (mean load)
7-19
SL3
“nnnnn”
Load sum with hoist cycles, the third power
7-20
SL8
“nnnnn”
Load sum with hoist cycles, the eight power
7-21
Power on
“nnnn” h
The total power on time for hoist control unit
7-22
Temp Index
“nnnn” h
The power on time weighted with the hoist control unit temperature
7-23
Max load
“nnnn” %
The maximum value of the measured load
7-24
Br Count
“nnnnn”
The brake wear counter. Counts the number of stop-actions to calculate the BrSWP%. Reset when the
hoisting brake has been replaced