10.4 Manual load calibration

Before starting the calibration, make sure you have a known test-load available of at least 80% and
maximum 130% of the nominal lifting capacity of the hoist

It is advisable to by-pass the overload protection during this calibration routine by setting the parameter

3-5 “OL protect” = OFF

The overload protection will automatically reset after 30 min. or after power off.

Lift the test load up until it hangs freely and steady.

Select parameter 3-4-1 “Load 1” and enter here the value of the test load (in tons)

Select parameter 1-2-10 “Ain1 value” and read the value

Select parameter 3-4-2 “Input 1” and enter here the value of parameter 1-2-10

Select parameter 1-2-1 “Act. Load”. The display should show “nnn”t (where “nnn” is the value of your
test load), ±5%. Repeat steps 1 to 4 until the value is within the desired range.

Lower the load and ensure the hook is empty

Select parameter 3-4-3 “Load 2” and enter here 0.00t

Select parameter 1-2-10 “Ain1 value” and read the value

Select parameter 3-4-4 “Input 2” and enter here the value of parameter 1-2-10

Select parameter 1-2-1 “Act. Load”. The display should show 0.00t, ±5%. Repeat steps 5 to 8 until the
value is within the desired range.