Appendix 7 - Replacing the condition monitoring unit

Read through all steps of these instructions and make yourself familiar with the procedure before
continuing!

Write down the following information:

Hoist’s order Number:

Hoist’s serial number:

Old unit serial number:

New unit serial number:

Fill in the requested fields of this document.

Follow the next steps to replace the Control Monitoring unit:

On the display are four pushbuttons for navigating and programming.

ESC

1. Zeroing of tare load. Press ESC button for three seconds.
2. Moving from submenu to main menu and reject parameter changes

1. Toggle between actual load (orange LED off) and tare load (orange LED on)
2. Scrolling down

1. Toggle between actual load (orange LED off) and tare load (orange LED on)
2. Scrolling up

ENT

1. Entering the password level
2. Selecting a menu and accept parameter changes

Enter password 2180

Read the parameter 4-7-1 value

-

Push 3 times Up button => Menu 4

-

Push Ent button => Menu 4-1

-

Push 6 times Up button => Menu 4-7

-

Push Ent button => Parameter 4-7-1
-

Check whether parameter shows Motor or Sens.

Write down the following parameters:

-

Push ESC-button 2 times => Menu 4

-

Push Down-button ones => Menu 3

-

Push ENT-button => Menu 3-1

-

Select menu 3-2 or 3-4 whit Up-button and push ENT-button

-

Read parameters’ values. Select parameter by Up- or Down-button