beautypg.com

5 register description – Rainbow Electronics AT86RF231 User Manual

Page 93

background image

93

8111A–AVR–05/08

AT86RF231

8.4.5

Register Description

Register 0x07 (PHY_ED_LEVEL):

The ED_LEVEL register contains the result of an ED measurement.

• Bit [7:0] - ED_LEVEL

The minimum ED value (ED_LEVEL = 0) indicates receiver power less than or equal to
RSSI_BASE_VAL. The range is 84 dB with a resolution of 1 dB and an absolute accuracy of
±5 dB. A manual ED measurement can be initiated by a write access to the register. A value
0xFF signals that a measurement has never been started yet (reset value).

The measurement duration is 8 symbol periods (128 µs) for a data rate of 250 kb/s.

For High Data Rate Modes the automated measurement duration is reduced to 32 µs, refer to

Section 11.3 “High Data Rate Modes” on page 137

. For manually initiated ED measurements in

these modes the measurement period is still 128 µs as long as the receiver is in RX_ON state.

A value other than 0xFF indicates the result of the last ED measurement.

Bit

7

6

5

4

3

2

1

0

+0x07

ED_LEVEL[7:0]

ED_LEVEL

Read/Write

R

R

R

R

R

R

R

R

Reset Value

1

1

1

1

1

1

1

1