Fault reprint, Ribbon low, Units – Printronix SL4M User Manual
Page 81: Set label length
![background image](/manuals/268582/81/background.png)
MEDIA SETUP Submenus
81
Fault Reprint
This option determines how the printer handles data that was printing when
an error occurred.
•
Disable
(factory default). The printer will not reprint the label that was
printing when the error condition occurred.
•
Enable
. The printer reprints the label that was printing when the error
condition occurred.
NOTE:
When Fault Reprint is set to Enable and a RIBBON OUT condition
occurs, some labels may not reprint. This depends on the label
length, print speed selected, and the additional time it takes to detect
this condition. Be sure to verify that all labels were reprinted after a
RIBBON OUT condition by using the Ribbon Low indicator as
described on page 81.
Ribbon Low
When enabled, and the ribbon remaining on the supply spindle is less than
1/8 full, the Attention indicator will flash, and "Ribbon Low" displays on the last
line of the LCD. A Ribbon Low warning will not prevent printing.
The options are Disable (factory default) and Enable.
The Ribbon Low submenu is available if Admin User is set to Enable in the
PRINTER SETUP menu.
Units
This item selects either millimeters or inches as the unit of measure.
The options are In Inches (factory default) and In Millimeters.
Set Label Length
This feature selects whether the Sensed Distance value derived from an Auto
or Manual Calibrate will be used to set the Label Length value in the MEDIA
SETUP menu.
•
Manual
(factory default). The Sensed Distance value derived from an
Auto or Manual Calibrate
will not
override
or change the Label Length
value.
•
Automatic
. When an Auto or Manual Calibrate is performed, the Sensed
Distance value derived from either calibrate
will override
and change the
Label Length value. If no Auto or Manual Calibrate is performed, the
current Label Length value will be used.
NOTE:
When Set Label Length = Automatic and Gap/Mark Sensor = Gap,
the printer will subtract the Gap Length value (in the SENSOR
SETUP menu) from the Sensed Distance value obtained when the
Auto or Manual Calibrate was performed.
If you set the label length to Automatic, the Enable setting for Use
Label Length under the Sensor Setup menu will be ignored.