Printronix SL4M User Manual
Page 146

146
Chapter
4
DIAGNOSTICS Menu
Software Build
This is the reference number which includes the program file part number and
revision number of the software installed in the printer, e.g., 358186 V1.07G.
Feature File
Displays the part number only when a feature file has been installed.
Hex Dump Mode
•
Disable
(factory default).
•
Enable
. The printer prints out data sent from the host in hexadecimal
format.
Auto Dump
•
Disable
(factory default).
•
Enable
. When the printer displays an E03x type message on the control
panel, a dump file is automatically created and stored in flash as
“autodbg1.dbg” or “autodbg2.dbg” in the printer file system. This file can
be uploaded to the host using the PrintNet Enterprise Suite application.
Upon receipt of this file, it should be sent to the Printronix Customer
Support Center for review and evaluation.
Print Error Log
Prints the current log of errors. Most non-routine faults (RIBBON FAULT,
PRINT HEAD HOT) are stored in the error log.
Clear Error Log
Clears entries in the error log.
FLASH Installed
Displays the amount of FLASH memory installed in megabytes.
EMC FLASH Installed
Displays the amount of EMC FLASH memory installed in megabytes.
DRAM Installed
Displays the amount of DRAM installed in megabytes.
Ptr On Time
Displays the cumulative time in hours the printer has been powered on. This
value is set to zero at the factory after burn-in testing.
Printer Usage
Displays the cumulative number of inches the printer has moved media. This
value is set to zero at the factory after burn-in testing.