Printer mgmt – Printronix SL4M User Manual
Page 138
![background image](/manuals/268582/138/background.png)
138
Chapter
4
INTERFACES Menu
•
Framing Errors
. These are possible errors that can occur when serial
interface settings of the printer do not match those of the host computer.
•
Enable
(factory default). If a framing error occurs, a fault message
will display on the control panel.
•
Disable
. If a framing error occurs, a fault message will not display on
the control panel.
•
Offline Process
•
Disable
(factory default). When set to disable, the printer does not
process serial data while offline.
•
Enable
. When set to enable, the printer continues to process (but not
print) the current serial job while the printer is offline until the printer's
buffer is full.
Printer Mgmt
•
PNE Port
. This menu selects which port the printer expects PNE to
connect to, via Ethernet, USB, or Serial. The factory default is Disable.
•
Mgmt Protocol
.
Since PXML and UCP management protocols share the
same Ethernet Port, only one can be active at a time. This menu selects
the active Management Protocol Interface, either PXML or UCP. The
factory default is PXML.
•
Select Port
•
Debug
(factory default). If the PNE Port is set to Serial then the PNE
will communicate through the Debug Serial Port.
•
Host
. If the PNE Port is set to Serial then the PNE will communicate
through the Host Serial Port. This cannot be selected if Host Interface
is set to Auto Switching or Serial.
Table 12. ENQ Status Byte
Bit
Printer Status
0
Set when the label has printed.
1
Set when the label is presented.
2
Set while the printer is online.
3
Always set.
4
Set printing in the batch mode.
5
Set during a Ribbon fault.
6
Set during a Paper Out fault.
7
Set during a Head Open fault.