Chapter 8 – Printronix P8000 Series Cartridge Ribbon Printer User Manual
Page 304

304
Chapter
8
Fault Messages (ASCII in Alphabetical Order)
PRINTER UNDER REMOTE
CONTROL
No
Status message: The
printer is under the
control of PrintNet
Enterprise (PNE) remote
management software.
No action is required.
PROCESSOR HALTED
EC_FAULT_RTSYS2
No
Real-time System
Firmware error on
controller board.
Contact your authorized
service representative.
1
PROTECTED INSTR*
No
Protected Instruction.
Firmware error on
controller board.
Contact your authorized
service representative.
1
PS/PDF ERROR:
CHECK ERROR
Yes
Fault displayed when
Postscript/PDF failed to
process a job. One or
more of the following
errors were detected:
Type Check, Limit Check,
Range Check, or No
Current Point Defined.
Check the Postscript/PDF job
for syntax (Postscript) errors.
Clear the fault. Postscript/PDF
will continue with the next job.
PS/PDF ERROR:
DICTIONARY ERROR
Yes
Fault displayed when
Postscript/PDF failed to
process a job. One or
more of the following
errors were detected:
Dictionary Full, Dictionary
Stack Overflow, or
Dictionary Stack
Underflow.
Check the Postscript/PDF job
for syntax (Postscript) errors.
Clear the fault. Postscript/PDF
will continue with the next job.
PS/PDF ERROR:
INVALID ACCESS
Yes
Fault displayed when
Postscript/PDF failed to
process a job. One or
more of the following
errors were detected:
Invalid Access, Invalid
Font, or Invalid Exit.
Check the Postscript/PDF job
for syntax (Postscript) errors.
Clear the fault. Postscript/PDF
will continue with the next job.
PS/PDF ERROR:
I/O ERROR
Yes
Fault displayed when
Postscript/PDF failed to
process a job. One or
more of the following
errors were detected: I/O
Error, Invalid File Access,
Undefined File, Interrupt,
or Time Out.
Check the Postscript/PDF job
for syntax (Postscript) errors.
Clear the fault. Postscript/PDF
will continue with the next job.
Table 23. LCD Message Troubleshooting Table (ASCII)
Displayed Message
Can User
Correct?
Explanation
Solution