P-series xq emulation, Control code 06, Define cr code – Printronix P8000 Series Cartridge Ribbon Printer User Manual
Page 153: Autowrap
P-Series XQ Emulation
153
P-Series XQ Emulation
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can
select an alternate line spacing of 6, 8, or 10.3 LPI.
Define CR Code
This option controls the action of the printer when it receives a Carriage
Return code (hex 0D) from the host computer. If this feature is enabled, each
time the printer receives a Carriage Return, it inserts an additional Line Feed
code (hex 0A) into the data stream. Do not use this feature if the host
computer sends line feeds to the printer.
•
CR = CR
(factory default). Does not insert an extra line feed after each
carriage return.
•
CR = CR + LF
. Inserts an extra line feed after each carriage return. The
next print position will be print position 1 of the next line.
Autowrap
This option defines the printer action when print data is received past the
forms width setting.
•
With LF+CR
(factory default). Performs an automatic carriage return and
line feed when data is received past the forms width.
•
With CR
. Performs an automatic carriage return (without line feed) when
data is received past the forms width.
•
Disable
. Discards any data past the forms width.
Printer
Protocol
(from page 125)
Control Code
06
Define CR
Code
Autowrap
Define LF
Code
Compressed
Elong/Alt.
Font
HS Print
VFU Select
Upr. Case
Select
Slew
Relative
8.0 LPI*
10.3 LPI
6.0 LPI
CR = CR*
CR = CR + LF
With LF+CR*
With CR
Disable
LF = CR + LF*
LF = LF
char 01 SOH*
char 03 ETX
char 09 HT
Elng=BS Font=SO*
Elng=SO Font=BS
char 02 STX*
char 03 ETX
char 09 HT
EVFU*
DVFU
CVFU
Disable
Disable*
Enable
1 to 15 lines*
1 to 16 lines
* = Factory Default
P-Series
XQ