Hor. quiet zone – Printronix P8000 Series Cartridge Ribbon Printer User Manual
Page 227
SURE SCAN Submenu
227
Hor. Quiet Zone
This menu defines the quiet zones (empty areas) width before and after the
start/stop codes regardless of picket fence or ladder orientation. When
positioning the barcode, the quiet zone is taken into account when detecting
collisions with other elements (dots) on the form. If one of the horizontal quiet
zones is violated, the barcode will automatically shift to the left or right (for
picket fence orientation) or up or down (for ladder orientation) to remove the
quiet zone violation.
The width of the area can be defined between 0 and 0.99 inches in 0.01 inch
increments. The default is 0.20 inches. This feature ensures that the
replacement barcodes will be properly scanned.
Barcodes are
automatically adjusted
away from text (or other
obstacles on the form)
until the Hor. Quiet
Zone distance is met.
Quiet Zone
distance
(picket)
Quiet Zone
distance
(ladder)