Graphic chek err, Graphic chek cod, Set text orientn – Printronix P8000 Series Cartridge Ribbon Printer User Manual
Page 122: Host override
122
Chapter
4
EMULATION Menu
Graphic Chek Err
Allows overriding of the host setting for the SGEA (Set Graphic Error Action)
command.
•
Enable
(factory default). The host setting for the SGEA used by the
printer. If the SGEA command is requested to stop on graphic errors, the
printer will stop when a graphic error is detected.
•
Disable
. Ignores the SGEA command from the host. The printer does not
stop when an error is detected; instead, it substitutes the character
selected in the Graphic Chek Code parameter.
Graphic Chek Cod
Specifies the replacement character to print in place of any unprintable
character that is received from the host. Choose a hex character from 40
through FE. The character becomes the printer default when:
•
The printer is powered off and then powered on.
•
An SGEA command specifies to use the operator panel default.
•
The Graphic Chek Err parameter is disabled.
The value can be the following:
•
60
(factory default)
•
40 – F4
Set Text Orientn
Specifies the direction in which characters are printed on the page. This
allows the printer to print languages which are printed right to left instead of
left to right.
•
Left to Right
(factory default)
•
Right to Left
. When a right to left language is selected, the host will be
notified of print direction changes when the printer is put online.
Host Override
Determines whether the printer accepts certain commands sent by the host,
or continues to use the current operator panel settings.
•
Disable
(factory default). Allows these host commands to override
operator panel settings: line length, forms length, lines per inch (LPI),
characters per inch (CPI), print quality, and text orientation. Note the
information appearing on the message display may not match the data
stream setting. No values will change upon initial selection of the disable
option.
•
Enable
. The operator panel settings override the host commands.