Fault Messages (ASCII in Alphabetical Order)
Half Speed Mode
No
Status message: The
controller samples the
operating temperature of
key components of the
print mechanism. When
higher than normal
temperatures are sensed,
the print speed is
automatically reduced by
50% and the message
sent the LCD. When the
components cool down,
the print speed returns to
100% and the message
clears.
No action is required. If the
message appears often,
contact your authorized
service representative.
1
HAMMER COIL BAD*
#, #, #, ...etc
No
Hammer coil # failed
current test at power up.
Contact your authorized
service representative.
1
HAMMER DRIVER
CIRCUIT BAD*
No
Driver Circuit Bad. The
hammer coil count test
failed.
Contact your authorized
service representative.
1
HAMMERBANK NOT
INSTALLED*
No
Hammer Bank Not
Installed. Self-test
routines do not detect
hammer coils at printer
start-up.
Contact your authorized
service representative.
1
HMR BANK FAN FLT
Yes
Sensor cannot detect
current in fan circuit.
Check that fan cable is
connected. Check for
obstruction of vents and fan
airway; remove any
obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on
the printer. If this message
recurs, contact your
authorized service
representative.
1
ILL EXT BUS ACC*
No
Illegal External Bus
Access. Firmware error
on the controller board.
Contact your authorized
service representative.
1
Table 23. LCD Message Troubleshooting Table (ASCII)
Displayed Message
Can User
Correct?
Explanation
Solution