beautypg.com

Define lf code, Character set, Printer select – Printronix P8000 Series Cartridge Ribbon Printer User Manual

Page 171: Esc c sequence, Reset cmd cfg ld, Received cr

background image

171

Define LF Code

Controls the action of the printer when it receives a Line Feed code (hex 0A)
from the host computer. If this feature is enabled, each time the printer
receives a line feed, it inserts an additional carriage return code (hex 0D) into
the data stream. This feature can be used in most installations, but it is
required if the host computer does not send carriage returns to the printer.

LF = CR + LF

(factory default). Adds an extra carriage return with each

line feed.

LF = LF

. Does not add a carriage return with a line feed.

Character Set

This parameter selects a character set for the ANSI emulation. Note that
when 0876 OCR-A or 0877 OCR-B is selected as the print language, the Font
Attributes Typeface parameter is changed to OCR-A or OCR-B, respectively.
Character sets are shown in detail in the

Character Sets Reference Manual

.

Printer Select

ON = DC1/OFF = DC3

(factory default). Disables the printer when a DC1

control code is received, and enables the printer when a DC3 control
code is received.

Disable

. Ignores the DC1 and DC3 control codes.

ESC c Sequence

Enable

(factory default). An ESC c code received from the host resets the

printer parameters to the factory defaults.

Disable

. An ESC c code received from the host is ignored.

Reset Cmd CFG Ld

When the printer receives a host data stream reset command

(ESC @ or ESC[K) in addition to resetting printer variables, the selected
configuration will be loaded.

Disable

(factory default). The active emulation parameters are loaded

when the reset command is executed.

Power-Up Config

. The power-up configuration is loaded when the reset

command is executed.

Current Config

. The currently selected configuration is loaded when the

reset command is executed.

Factory Config

. The factory installed configuration is loaded when the

reset command is executed.

Received CR

Observe

(factory default). A CR code received from the host is handled

as a carriage return.

Ignore

. A CR code received from the host is ignored.

ANSI Emulation