Host override, Format control, Max. print width – Printronix P8000 Series Cartridge Ribbon Printer User Manual
Page 118

118
Chapter
4
EMULATION Menu
Host Override
Determines whether the printer accepts certain commands sent by the host,
or continues to use the current operator panel settings.
•
Disable
(factory default). Allows these host commands to override
operator panel settings: line length, forms length, lines per inch (LPI),
characters per inch (CPI), print quality, and text orientation. Note the
information appearing on the message display may not match the data
stream setting. No values will change upon initial selection of the disable
option.
•
Enable
. The operator panel settings override the host commands.
Format Control
Enables the printer to reflect the same spacing as CTPC model printers after
absolute and relative move commands are executed.
•
Disable
(factory default). Reflects distance, generated by the VGL
feature, PGL feature, and Hex Transparent control code sequence, in the
new position (after horizontal and vertical tabs are executed).
•
Enable
.
Max. Print Width
Set the maximum print width the printer will print when using a C/T host
interface. Set for 13.2 inches when printing files larger than the width of the
printer. All data exceeding the width of the maximum Printer Width will be
truncated.
•
13.2 inches
(factory default)
•
Printer Width
(the maximum width of the printer)