Reset to Factory Defaults
Reset to Factory Defaults
Reset to Factory Defaults
Reset to Factory Defaults
Reset to Factory Defaults
This parameter is used to reset all scale
submenu parameters to the factory de-
fault settings outlined in the following table.
To reset to the factory defaults,
press
ENTER
when “rESEt” is displayed.
Averaging Level
Averaging Level
Averaging Level
Averaging Level
Averaging Level
Averaging level compensates for vibra-
tion or excessive air currents on the load
receiver. During operation the I150 con-
tinually takes weight readings from the
load cell. Successive readings are then
averaged to achieve a stabilized display.
This parameter specifies whether the I150
will average more or fewer successive
readings. Select one of four averaging
levels.
To select an averaging level:
Enter the desired level (0, 1, 2, or 3)
using the numeric keypad, then press
ENTER
to return to the scale sub-
menu.
Minimum
Averaging
Maximum
Averaging
PARAMETER
LFT = OFF
LFT = ON
(Menu changes
(Menu changes
disabled w/jumper)
enabled)
Averaging Level
3
3
3
Stability Range
0.5 grad
unchanged
0.5 grad
Unit Selection
all units = ON
lb, kg = ON
lb, kg = ON
Auto Zero Tracking
0.5 grad
unchanged
0.5 grad
Custom Unit Exponent
0
N/A
N/A
Custom Unit Mantissa
1.0
N/A
N/A
Average Display
1
N/A
N/A
PC Error Level
100%
N/A
N/A
Set Point
OFF
OFF
OFF
Store
Tare
Tare
Tare
Retain
OFF
OFF
OFF
ENTER