Reference [Other Functions]

ZOOM MRS-802

137

Switching the level meter
display type

The level meter below the display can indicate the level of

the signal before passing through the level controls/faders

(pre-fader) or after passing through the level controls/faders

(post-fader). You can change the setting as follows.

1.

From the main screen, press the [UTILITY] key in

the display section.

The utility menu appears.

2.

Use the cursor left/right keys to bring up the

indication “UTILITY SYSTEM” on the display, and

press the [ENTER] key.

The system utility menu for making various system settings

appears.

3.

Use the cursor left/right keys to bring up the

indication “SYSTEM LVL MET” on the display, and

press the [ENTER] key.

The current level meter setting will be displayed.

The setting has the following meaning.

• POST

The meters show the level of the signal after passing through

the [REC LEVEL] controls/faders (default setting).

• PRE

The meters show the level of the signal before passing

through the [REC LEVEL] controls/faders.

4.

Turn the dial to change the setting.

5.

To return to the main screen, press the [EXIT] key

several times.

Hard disk maintenance

This section describes how to test and restore the integrity of

data on the internal hard disk, and how to perform other hard

disk maintenance functions.

Basic maintenance procedure

The procedure for hard disk maintenance is the same for

most operations. The basic procedure is as follows.

1.

Turn power to the MRS-802 off. While holding

down the [CLEAR] key, turn power on again.

The MRS-802 starts up in “ROM utility mode” which serves

for performing special functions.

2.

Press the [MARK] key in the control section.

The indication “ExtFunc Select” appears on the display.

3.

Use the cursor left/right keys to select the desired

command.

The following commands are available.

• ScanDisk

Test and repair the integrity of data stored on the internal

hard disk.

• Init Fac (Factory Initialize)

Restore files and data necessary for operation such as the

system files. Data created by the user will not be erased.

• Init ALL (All Initialize)

Format the internal hard disk and then restore files and data

necessary for operation such as the system files. All existing

projects on the hard disk will be erased.

4.

Press the [ENTER] key to execute the command.

Subsequent display indications and operation steps differ for

the individual commands. See the respective section below.