Battery Status Meter (TM500A)
The TM500A features six data monitoring functions and three indicators
including:
•
State-of-charge/amp-hour content (full or percent of capacity)
•
State-of-charge/voltage (real-time voltage level, historical high and
low system voltage)
•
Amps (real-time amps, total charging amps, total load amps)
•
Amp hours removed
•
Days since fully charged
•
Cumulative amp hours
•
Recharge indicator
•
Low-voltage indicator
•
Full-charge indicator
The unit is configurable for specific system or application functions such
as setting the CHARGED indication parameters, battery capacity,
charging efficiency, low-battery warning conditions and a recharge
reminder. The TM500A can monitor any battery supply from
approximately 8 to 65 volts, track energy consumption, and estimate
remaining battery life.
The TM500A operates on 12-, 24-, or 48-volt battery systems (48-volt
systems require an optional shunt board).
Figure 2-7 DC250 Disconnect Box and TM500A Battery Status Meter
DC250