Xantrex Technology SW Plus 4024 User Manual
Page 181
![background image](/manuals/229206/181/background.png)
Advanced Setup Summary
976-0043-01-02
7–3
21C Grid Usage End h:m
00:00 to 23:50
21:00
00:00 to 23:50
21:00
End Menu 21
22 Battery Xfer (BX) Menu
“22 Battery Xfer (BX) Menu” on page 7–18
for details.
22A High Xfer (HBX) Vdc
16.1 to 33.9
27.0
32.2 to 67.8
54.0
22B Low Xfer (LBX) Vdc
16.1 to 33.8
23.0
32.2 to 67.8
46.0
End Menu 22
23 ALM Relays Menu
“23 ALM Relays Menu” on page 7–19
for details.
23A RY9 VDC Energized
22.1 to 35.5
26.0
44.2 to 71.0
52.0
23B RY9 VDC DeEnergized
20.0 to 35.5
22.0
40.0 to 71.0
44.0
23C RY9 Delay at DeEngz.
Min
00 to 255
10
00 to 255
10
23D RY10 VDC Energized
10.0 to 32.0
28.8
20.0 to 64.0
57.6 Vdc
23E RY10 VDC DeEnergized
10.0 to 32.0
26.8
20.0 to 64.0
53.6 Vdc
23F RY10 Delay at DeEngz.
Min
00 to 255
10
00 to 255
10
23G RY11 Mode
Cooldown Error Error
Cooldown Error Error
End Menu 23
24 Generator Timers Menu
“24 Generator Timers Menu” on page 7–26
for details.
24A Gen Run Time Start h:m
00:00 to 23:50
08:00
00:00 to 23:50
08:00
24B Gen Run Time Stop h:m
00:00 to 23:50
08:00
00:00 to 23:50
08:00
24C Quiet Time Begin h:m
00:00 to 23:50
08:00
00:00 to 23:50
08:00
24D Quiet Time End h:m
00:00 to 23:50
08:00
00:00 to 23:50
08:00
24E Gen Exercise Period Days 00 to 255
30
00 to 255
30
24F Gen Exercise Timer Min
00 to 255
15
00 to 255
15
24G Gen Cooldown Timer
Min
00 to 255
02
00 to 255
02
24H RN2/Max Gen Run h:m
00:00 to 23:50
08:00
00:00 to 23:50
08:00
End Menu 24
25 Gen Starting Details Menu
“25 Gen Starting Details Menu” on page 7–29
for details.
Table 7-1 Advanced Setup Default Settings for the
Sine Wave Plus
2524 and 2548 Models
Advanced Setup Menus
Sine Wave Plus
2524
Sine Wave Plus
2548
See Page
Range/Display
Default
Settings
Range/Display
Default