Configuration Settings
B–12
976-0043-01-02
26G Read LBCO 30 sec Start
LBCO
setting (11C)
22.0
LBCO
setting (11C)
44.0
27 Save/Restore Setup Menu
“27 Save/Restore Settings Menu” on page 7–39
for details.
27A Push INV now to save
Settings
Push INV now to save Settings
27B Push GEN to restore settings
Push GEN to restore settings
27C Push GEN for Factory
Defaults
PUSH GEN for Factory Defaults
Table B-5 Advanced Setup Default and User Settings for the Sine Wave Plus 2524 and
2548 Models
Advanced Setup Menus
Sine Wave Plus
2524
Sine Wave Plus
2548
User
Settings
Range/
Display
Default
Settings
Range/
Display
Default
Settings
Table B-6 Advanced Setup Default and User Settings for the Sine Wave Plus 4024 and
4048 Models
Advanced Setup Menus
Sine Wave Plus
4024
Sine Wave Plus
4048
User
Settings
Range/
Display
Default
Settings
Range/
Display
Default
Settings
20 Silent Setup Menu
“20 Silent Setup Menu” on page 7–13
for details.
20A Refloat High Volts DC
16.1 to 33.9
28.4
32.2 to 67.8
56.8
20B Refloat Low Volts DC
16.1 to 33.8
25.0
32.2 to 67.8
50.0
20C Float Done Amps AC
00 to 40
10
00 to 40
10
20D Must Float Time Min
00 to 255
05
00 to 255
05
21 Grid AC1 Usage Menu
“21 Grid (AC1) Usage Menu” on page 7–16
for details.
21A Grid Usage SB BX
SB BX
SB
SB BX
SB
21B Grid Usage Begin h:m
00:00 to 23:50 21:00
00:00 to 23:50 21:00
21C Grid Usage End h:m
00:00 to 23:50 21:00
00:00 to 23:50 21:00
22 Battery Xfer (BX) Menu
“22 Battery Xfer (BX) Menu” on page 7–18
for details.
22A High Xfer (HBX) Vdc
16.1 to 33.9
27.0
32.2 to 67.8
54.0
22B Low Xfer (LBX) Vdc
16.1 to 33.8
23.0
32.2 to 67.8
46.0
23 ALM Relays Menu
“23 ALM Relays Menu” on page 7–19
for details.