The user menu summary, Table 8-2 user menu, The user menu summary –11 – Xantrex Technology SW Plus 4024 User Manual
Page 229: Table 8-2, User menu –11
![background image](/manuals/229206/229/background.png)
The User Menu Summary
976-0043-01-02
8–11
The User Menu Summary
The User Menu provides all the controls and settings that may be required
on a daily basis such as turning ON the inverter and/or generator, reading
the AC and DC meters, checking the possible causes of an error, or
adjusting the inverter’s real-time clock.
Most menu headings in the User Menu do not set configuration
parameters (Read Only) but do provide system performance information.
Those menu items which are not specified as “Read Only” may be
configured through the user menu.
Table 8-2 User Menu
User Menus
Sine Wave Plus
2524 and 4024
Sine Wave Plus
2548,4048, and 5548
See Page
Range/
Display
Default
Settings
Range/
Display
Default
Settings
01 Inverter ON/OFF Menu
“01 Inverter ON/OFF Menu” on page 8–15
for details.
01A Inverter
OFF SRCH
ON CHR
OFF
OFF SRCH
ON CHR
OFF
01B EQ Charge
OFF ON
OFF
OFF ON
OFF
01C Search Watts (SRCH)
00 to 248
08
00 to 248
08
01D Bypass Mode
AC1 NORM
AC2
NORM
AC1 NORM
AC2
NORM
End Menu 01
02 Generator ON/OFF Menu
“02 Generator ON/OFF Menu” on page 8–17
for details.
02A Generator
OFF AUTO
ON
OFF
OFF AUTO
ON
OFF
02B Gen Start Load Amps
YES NO
Read Only
YES NO
Read Only
02C Gen Start Volts/Manual
YES NO
Read Only
YES NO
Read Only
02D Gen Start Exercise Run
YES NO
Read Only
YES NO
Read Only
02E Gen Start Run Time
YES NO
Read Only
YES NO
Read Only
02F Days left to Gen Exercise
00 to 255
Read Only
00 to 255
Read Only
End Menu 02
03 Time of Day (00:00:00)
“03 Time Of Day Menu” on page 8–20
for details.
SW Plus
Version 2.01
Info.
Displayed
Read Only
Info.
Displayed
Read Only
X.X KVA ** 120 Vac 60 Hz
(where X.X = 2.5, 4.0 or 5.5)
**24 Vdc
Read Only
**48 Vdc
Read Only