beautypg.com

4 command summary, 52 9.4 command summary – ZyXEL Communications ZyXEL Dimension ES-2024PWR User Manual

Page 52

background image

Chapter 9 CFM Commands

Ethernet Switch CLI Reference Guide

52

9.4 Command Summary

The following section lists the commands for this feature.

Table 28 CFM Command Summary

COMMAND

DESCRIPTION

M

P

clear ethernet cfm linktrace

Clears the link trace database.

E

13

clear ethernet cfm mep-ccmdb

Clears the MEP CCM database.

E

13

clear ethernet cfm mip-ccmdb

Clears the MIP CCM database.

E

13

clear ethernet cfm mep-defects

Clears the MEP-defects database.

E

13

ethernet cfm

Enables CFM on the Switch.

C

13

ethernet cfm md <md-index> format
name <md-name>
level <0-7>

Creates an MD (Maintenance Domain) with the specified

name and level number.
md-name: Enters a domain name, MAC address or a

descriptive name for the MD.

C

13

ethernet cfm ma <ma-index> format
name <ma-name>
md <md-index> primary-vlan <1-4094>

Creates an MA (Maintenance Association) and defines

its VLAN ID under the MD. You can also define the

format which the Switch uses to send this MA information

in the domain (MD).
ma-name: Enters a VLAN ID, a descriptive name or a 2-

octet integer for the MA.

Note: If you set the format to vid, the VLAN

ID should be the same as the VLAN ID
you use to identify the MA.

C

13

cc-interval
<100ms|1s|10s|1min|10min>

Sets how often an MEP sends a connectivity check

message (CCM).

C

13

mhf-creation < none | default |
explicit>

Sets MHF (MIP Half Function).
Select none and no MIP can be created automatically for

this MA.
Select default to automatically create MIPs for this MA

and on the ports belonging to this MA’s VLAN when there

are no lower configured MD levels or there is an MEP at

the next lower configured MD level on the port.
Select explicit to automatically create MIPs for this

MA and on the ports belonging to this MA’s VLAN only

when there is an MEP at the next lower configured MD

level on the port.

C

13

id-permission < none | chassis
| management | chassis-
management>

Sets what’s to be included in the sender ID TLV (Type-

Length-Value) transmitted by CFM packets.
Select none to not include the sender ID TLV.
Select chassis to include the chassis information.
Select management to include the management

information.
Select chassis-management to include both chassis

and management information.

C

13

exit

Exits from the config-ma mode.

C

13

remote-mep <mep-id>

Sets a remote MEP in an MA.

C

13

mep <mep-id> interface port-
channel <port> direction
priority <0-7>

Sets an MEP in an MA.
up|down: The traffic direction.
0-7: The priority value of the CCMs or LTMs transmitted

by the MEP. 1 is the lowest, then 2, 0 and 3 ~ 7.

C

13