Chapter 73 Additional Commands
Ethernet Switch CLI Reference Guide
255
This example shows the current and recent CPU utilization.
The following table describes the labels in this screen.
suppressAlarm
This field displays whether or not the alarm is inactive.
alarmLED
This field displays whether or not the LED for this alarm is on.
sysname# show cpu-utilization
CPU usage status:
baseline 1715384 ticks
sec ticks util sec ticks util sec ticks util sec ticks
util
--- ------- ------ --- ------- ------ --- ------- ------ --- -------
0 657543 61.67 1 255118 85.13 2 394329 77.01 3 620008
63.85
4 195580 88.60 5 791000 53.89 6 137625 91.98 7 508456
70.36
--------------------------------- SNIP ---------------------------------
Table 154 show cpu-utilization
LABEL
DESCRIPTION
baseline
This field displays the number of CPU clock cycles per second.
sec
This field displays the historical interval.
Interval 0 is the time starting one second ago to the current instant.
Interval 1 is the time starting two seconds ago to one second ago.
Interval 2 is the time starting three seconds ago to two seconds ago.
ticks
This field displays the number of CPU clock cycles the CPU was not used
during the interval.
util
This field displays the CPU utilization during the interval.
util = [(baseline - ticks) / baseline] * 100