Chapter 73 Additional Commands

Ethernet Switch CLI Reference Guide

255

This example shows the current and recent CPU utilization.

The following table describes the labels in this screen.

suppressAlarm

This field displays whether or not the alarm is inactive.

alarmLED

This field displays whether or not the LED for this alarm is on.

sysname# show cpu-utilization
CPU usage status:
baseline 1715384 ticks
sec ticks util sec ticks util sec ticks util sec ticks
util
--- ------- ------ --- ------- ------ --- ------- ------ --- -------
0 657543 61.67 1 255118 85.13 2 394329 77.01 3 620008
63.85
4 195580 88.60 5 791000 53.89 6 137625 91.98 7 508456
70.36
--------------------------------- SNIP ---------------------------------

Table 154 show cpu-utilization

LABEL

DESCRIPTION

baseline

This field displays the number of CPU clock cycles per second.

sec

This field displays the historical interval.
Interval 0 is the time starting one second ago to the current instant.
Interval 1 is the time starting two seconds ago to one second ago.
Interval 2 is the time starting three seconds ago to two seconds ago.

ticks

This field displays the number of CPU clock cycles the CPU was not used

during the interval.

util

This field displays the CPU utilization during the interval.
util = [(baseline - ticks) / baseline] * 100

Table 153 show alarm-status (continued)

LABEL