beautypg.com

ZyXEL Communications ZyXEL Dimension ES-2024PWR User Manual

Page 252

background image

Chapter 73 Additional Commands

Ethernet Switch CLI Reference Guide

252

boot image

<1|2>

The Switch supports dual firmware images, ras-0 and ras-1.

Run this command, where is 1 (ras-0) or 2 (ras-1) to

specify which image is updated when firmware is loaded

using the web configurator and to specify which image is

loaded when the Switch starts up.

E

13

cable-diagnostics <port-list>

Perform a physical wire-pair test of the Ethernet connections

on the specified port(s).
Ok: The physical connection between the wire-pair is okay.
Open: There is no physical connection between the wire-pair.

E

13

ping <ip|host-name> [vlan <vlan-
id
>] [size <0-1472>] [-t]

Sends Ping packets to the specified Ethernet device.
vlan-id: Specifies the VLAN ID to which the Ethernet

device belongs.
size <0-1472>: Specifies the size of the Ping packet.
-t: Sends Ping packets to the Ethernet device indefinitely.

Press [CTRL]+C to terminate the Ping process.

E

0

ping help

Provides more information about the specified command.

E

0

reload config [1|2]

Restarts the system (warm reboot) with the specified

configuration file.
1: config-1
2: config-2

E

13

reset slot <slot-list>

Restarts the card in the selected slot. The card restarts using

the last-saved configuration. Any unsaved changes are lost.

E

13

show al1arm-status

Displays alarm status.

E

0

show cpu-utilization

Displays the CPU utilization statistics on the Switch.

E

0

show hardware-monitor

This command is not available in all models.
Displays current hardware monitor information with the

specified temperature unit (Celsius C or Fahrenheit F).

E

0

show memory

Displays the memory utilization statistics on the Switch.

E

3

show power-source-status

Displays the status of each power module in the system.

E

0

show sfp <port-list>

Displays real-time SFP (Small Form Facter Pluggable)

transceiver operating parameters on specified SFP port(s).

The parameters include, for example, module temperature,

module voltage, transmitting and receiving power.

E

3

show interfaces transceiver
<port-list>

Displays real-time SFP (Small Form Facter Pluggable)

transceiver information and operating parameters on

specified SFP port(s). The parameters include, for example,

module temperature, module voltage, transmitting and

receiving power.

E

3

show slot

Displays general status information about each slot.

E

13

show slot config

Displays what type of card is installed in each slot and its

current operational status.

E

13

show slot config <slot-list>

Displays detailed information about the specified slots.

E

13

show system-information

Displays general system information.

E

0

show version [flash]

Display the version of the currently running firmware on the

Switch. Optionally, display the version of the currently

installed firmware on the flash memory.

E

0

test interface port-channel
<port-list>

Performs an internal loopback test on the specified ports. The

test returns Passed! or Failed!.

E

13

Table 150 Command Summary: Additional Enable Mode (continued)

COMMAND

DESCRIPTION

M

P