beautypg.com

ZyXEL Communications ZyXEL Dimension ES-2024PWR User Manual

Page 259

background image

Chapter 73 Additional Commands

Ethernet Switch CLI Reference Guide

259

This example displays run-time SFP (Small Form Facter Pluggable) parameters on ports 9 (the
first SFP port 0, with an SFP transceiver installed) and 10 (the second SFP port 1, no SFP
transceiver installed) on the

Switch

. You can also see the alarm and warning threasholds

for

temperature, voltage, transmission bias, transmission and receiving power as shown.

This example runs an internal loopback test on ports 3-6.

This example displays route information to an Ethernet device with IP address

192.168.1.100

.

sysname# show sfp 9-10

SFP : 0
Part Number : SFP-SX-DDM
Series Number : S081113001132
Revision : V1.0
Transceiver : 1000BASE-SX
Temperature(C) Alarm(80.00 ~ 0.00), Warning(75.00 ~ 5.00), Current(38.00)
Voltage(V) Alarm(3.50 ~ 3.10), Warning(3.45 ~ 3.15), Current(3.37)
Tx Bias(mA) Alarm(100.05 ~ 1.00), Warning(90.04 ~ 2.00), Current(5.25)
Tx Power(dBm) Alarm(-2.99 ~ -8.98), Warning(-3.49 ~ -8.48), Current(-6.05)
Rx Power(dBm) Alarm(-2.99 ~ -18.01), Warning(-3.49 ~ -17.39), Current(-4.24)

SFP : 1
Not Available

sysname# test interface port-channel 3-6
Testing internal loopback on port 3 :Passed!
Ethernet Port 3 Test ok.
Testing internal loopback on port 4 :Passed!
Ethernet Port 4 Test ok.
Testing internal loopback on port 5 :Passed!
Ethernet Port 5 Test ok.
Testing internal loopback on port 6 :Passed!
Ethernet Port 6 Test ok.

sysname> traceroute 192.168.1.100
traceroute to 192.168.1.100, 30 hops max, 40 byte packet
1:192.168.1.100 (10 ms) (10 ms) (0 ms)
traceroute done:
sysname>