TMP92CM22

2007-02-16

92CM22-64

Port 9 Register

7 6 5 4 3 2 1 0

Bit

symbol

P92

P91

P90

Read/Write

R/W

After reset

Data from external port

(Output latch register is set to 1)

Port 9 Control Register

7 6 5 4 3 2 1 0

Bit

symbol

P92C

P91C

P90C

Read/Write

W

After

reset

0

0

0

Function

0: Input 1: Output

Port 9 Function Register

7 6 5 4 3 2 1 0

Bit

symbol

P92F

P91F

P90F

Read/Write

W

After

reset

0

0 0

Function

0:

Port,

SI

1: SCL

Note

0: Port

1: SO,

SDA

0: Port,

SCK input

1:SCK output

Note

Port 9 ODE Register

7 6 5 4 3 2 1 0

Bit

symbol

P92ODE

P91ODE

Read/Write

W

After

reset

0

0

Function

1:Open drain

1:Open drain

Note1: Read-modify-write instruction is prohibited for the registers P9CR, P9FC, and P9ODE.

Note2: When using SI and SCK input function, set P9FC to “0” (Function setting).

Figure 3.5.15 Register for Port 9

P9FC

(0027H)

P9

(0024H)

P9CR

(0026H)

P9ODE

(0025H)

P9CR

(0026H)

P9FC

(0027H)