Operation of Each Circuit

(1) Prescaler

A 9-bit prescaler generates the input clock to TMRA01.
The prescaler’s operation can be controlled using TA01RUN in the

timer control register. Setting to “1” starts the count; setting
to “0” clears the prescaler to “0” and stops operation. Table 3.7.2 shows
the various prescaler output clock resolutions.

Table 3.7.2 Prescaler Output Clock Resolution

Timer counter input clock

TMRA prescaler

TAxMOD

Clock gear

selection

SYSCR1

System clock

selection

SYSCR1

φT1(1/2)

φT4(1/8)

φT16(1/32) φT256(1/512)

000 (1/1)

fc/16

fc/64

fc/256

fc/4096

001 (1/2)

fc/32

fc/128

fc/512

fc/8192

010 (1/4)

fc/64

fc/256

fc/1024

fc/16384

011 (1/8)

fc/128

fc/512

fc/2048

fc/32768

100 (1/16)

0 (fc)

1/8

fc/256 fc/1024

fc/4096

fc/65536

(2) Up counters (UC0 and UC1)

These are 8-bit binary counters which count up the input clock pulses for the clock

specified by TA01MOD.
The input clock for UC0 is selectable and can be either the external clock input via the
TA0IN pin or one of the three internal clocks

φT1, φT4, or φT16. The clock setting is

specified by the value set in TA01MOD.

The input clock for UC1 depends on the operation mode. In 16-bit timer mode, the

overflow output from UC0 is used as the input clock. In any mode other than 16-bit
timer mode, the input clock is selectable and can either be one of the internal clocks
φT1, φT16, or φT256, or the comparator output (The match detection signal) from
TMRA0.

For each interval timer the timer operation control register bits

TA01RUN and TA01RUN can be used to stop and clear the up
counters and to control their count. A reset release both up counters, stopping the
timers.