TMP92CM22

2007-02-16

92CM22-246

(9) I

2

C bus/Serial channel (1/2)

Symbol Name

Address

7 6 5 4 3 2 1 0

BC2 BC1 BC0 ACK SCK2

SCK1

SCK0/

SWRMON

W R/W

W

R/W

0 0 0 0 0 0 0/1

1240H

(Prohibit

RMW)

I

2

C mode

Number of transfer bits
000: 8

001: 1

010: 2

011: 3

100: 4

101: 5

110: 6

111: 7

Acknowledge

mode

0: Disable
1: Enable

Setting of the divide value “n”
000: 5

001: 6

010: 7

011: 8

100: 9

101: 10 110: 11

111: Reserved

SIOS SIOINH

SIOM1

SIOM0

SCK2 SCK1 SCK0

W

W

0 0 0 0 0 0 0

SBI0CR1

SBI0

control

register 1

1240H

(Prohibit

RMW)

SIO mode

Transfer

0: Stop
1: Start

Transfer

0: Continue
1: Abort

Transfer mode

00: 8-bit transmit
10: 8-bit transmit/receive
11: 8-bit receive


Setting of the divide value “n”

000:4 001:5 010:6 011:7

100:8 101:9 110:10

111:External clock SCK0

DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0

R (Receiving)/W (Transmission)

SBI0DBR

SBI0

buffer

register

1241H

(Prohibit

RMW)

Undefined

SA6 SA5 SA4 SA3 SA2 SA1 SA0 ALS

W

0 0 0 0 0 0 0 0

I2C0AR

I

2

C bus0

address

register

1242H

(Prohibit

RMW

Setting slave address

Address
recognition

0 :Enable
1: Disable

MST TRX BB PIN

AL/SBIM1

AAS/

SBIM0

AD0/

SWRST

LARB/

SWRST0

W

0 0 0 1 0 0 0 0

SBI0SR

when read

Serial bus

interface

status

register

Bus status
monitor

0: Free
1: Busy

Arbitration
lost

detection
monitor

0:

1: Detect

Slave
address
match
detection
monitor

0: Undetect

1: Detect

GENERAL
CALL
detection
monitor

0:Undetect

1: Detect

Last
received bit
monitor
0: 0

1: 1

SBI0CR2

when write

Serial bus

interface

control

register2

1243H

(I

2

C mode)

(Prohibit

RMW)

0: Slave
1: Master

0: Receive
1: Transmit

Start/stop
condition
generation

0: Start

condition

1: Stop

condition

INTSBE0
request
monitor

0: Request
1: Cancel

Serial bus interface
operating mode
selection
00: Port mode
01: SIO mode
10: I

2

C bus mode

11: (Reserved)

Software reset
generate write “10”
and “01”, then an
internal reset signal is
generated.

SIOF/

SBIM1

SEF/

SBIM2

R/W W

0 0 0 0

SBI0SR

when read

Serial bus

interface

status

register

Transmit
status monitor

0: Stopped

1: Terminated

in progress

Shift operation
status monitor

0: Stopped

1: Terminated

in progress

SBI0CR2

when write

Serial bus

interface

control

register2

1243H

(SIO mode)

(Prohibit

RMW)

Serial bus interface
operating mode
selection

00: Port mode
01: SIO mode
10: I

2

C bus mode

11: (Reserved)

Always
write “0”.

Always
write “0”.

This manual is related to the following products: