3 ad conversion characteristics, 4 event counter (ta0in, tb1in0, and tb1in1) – Toshiba H1 SERIES TLCS-900 User Manual
Page 225

TMP92CM22
2007-02-16
92CM22-223
4.3
AD Conversion Characteristics
Parameter Symbol
Min
Typ.
Max
Unit
Analog reference voltage (
+) V
REFH
VCC
− 0.2
VCC VCC
Analog reference voltage (
−) V
REFL
VSS
VSS
VSS
+ 0.2
AD converter power supply voltage
A
VCC
VCC
VCC
VCC
AD converter power supply ground
A
VSS
VSS
VSS
VSS
Analog input voltage
A
VIN
VREFL
VREFH
V
Analog current for analog reference voltage
= 1
I
REF
1.0
1.2
mA
Analog current for analog reference voltage
= 0
0.02
5.0
UA
Total error
(Include quantize error of
± 0.5 LSB )
E
T
±1.0
±4.0 LSB
4.4
Event Counter (TA0IN, TB1IN0, and TB1IN1)
Variable
f
SYS
=
20 MHz
(fc
= 40 MHz)
f
SYS
=
125 kHz
(fc
= 4 MHz)
Parameter Symbol
MIN MAX
MIN
MAX
MIN
MAX
Unit
Clock cycle
T
VCK
8X
+
100
500 64100 ns
Low-level clock width
T
VCKL
4X
+
40
240 32040 ns
High-level clock width
T
VCKH
4X
+
40
240 32040 ns
Note: Symbol “x” in the above table means the period of clock “f
SYS
”, it’s same period of the system clock “f
SYS
” for
CPU core. The period of f
SYS
depends on the clock gear setting or changing high-speed oscillator/low-speed
oscillator and so on.