Figure 3.12.5 watchdog timer control register – Toshiba H1 SERIES TLCS-900 User Manual
Page 216

TMP92CM22
2007-02-16
92CM22-214
7 6 5 4 3 2 1 0
Bit symbol
WDTE
WDTP1
WDTP0
− I2WDT
RESCR
−
WDMOD
(1300H)
Read/Write R/W
R/W
After
reset
1 0 0 0 0 0 0
Function
WDT
control
1: Enable
Select detecting time
00: 2
15
/f
IO
01: 2
17
/f
IO
10: 2
19
/f
IO
11: 2
21
/f
IO
Always
write “0”
IDLE2
0: Stop
1: Operate
1: Internally
connects
WDT out
to the
reset pin
Always
write “0”
Watchdog timer out control
0
−
1
Connects WDT out to a reset
IDLE2 control
0
Stop
1
Operation
Watchdog timer detection time
00
2
15
/fIO (Approximately 3.28 ms at f
OSCH
= 40 MHz)
01
2
17
/f
IO
(Approximately 1.31 ms at f
OSCH
= 40 MHz)
10
2
19
/f
IO
(Approximately 52.4 ms at f
OSCH
= 40 MHz)
11
2
21
/f
IO
(Approximately 210 ms at f
OSCH
= 40 MHz)
Watchdog timer enable/disable control
0
Disabled
1
Enabled
Figure 3.12.4 Watchdog Timer Mode Register
7 6 5 4 3 2 1 0
Bit symbol
−
WDCR
(1302H)
Read/Write W
After reset
−
Read
-modify
-write
instruction
is prohibited
Function
B1H: WDT disable code
4EH: WDT clear code
WDT disable/clear control
B1H Disable
code
4EH Clear
code
Others Don’t
care
Figure 3.12.5 Watchdog Timer Control Register