beautypg.com

Port section equivalent circuit diagram – Toshiba H1 SERIES TLCS-900 User Manual

Page 253

background image

TMP92CM22

2007-02-16

92CM22-251

6.

Port Section Equivalent Circuit Diagram

■ Reading the circuit diagram

Basically, the gate symbols written are the same as those used for the standard CMOS logic

IC [74HCXX] series.

The dedicated signal is described below.
STOP: This signal becomes active “1” when the halt mode setting register is set to the STOP

mode and the CPU executes the HALT instruction. When the drive enable bit is set
to “1”, however, STOP remains at “0”.

The input protection resistance ranges from several tens of ohms to several hundreds of

ohms.

■ Data bus (D0 to D7), P1 (D8 to D15), P4 (A0 to A7), P5 (A8 to A15), P6 (A16 to A23),

P76 (

WAIT

), PD2 (TB1OUT0), PD3 (TB1OUT1), PF6, and PF7

■ P90 (SCK), PC0 (TA0IN), PC1 (TA1OUT/INT1), PC3 (INT0), PC5 (TA3OUT/INT2), PC6

(TB0OUT/INT3), PD0 (INT4/TB1IN0), PD1 (INT5/TB1IN1), PF1 (RXD0), PF2 (SCLK0/

CTS0

),

PF4 (RXD1), and PF5 (SCLK1/

CTS1

)

VCC

Output data

Output enable

Stop

Input data

I/O

Input enable

P-ch

N

-ch

VCC

Output data

Output enable

Stop

Input data

I/O

Input

enable

P-ch

N-ch

This manual is related to the following products: