Recommended operating conditions (continued) – Texas Instruments Dual/Single Socket CardBus and UntraMedia Controller PCI7621 User Manual
Page 293

14−3
Recommended Operating Conditions (continued)
OPERATION
MIN
NOM
MAX
UNIT
S100 operation
±
1.08
Receive input jitter
TPA, TPB cable inputs
S200 operation
±
0.5
ns
Receive input jitter
TPA, TPB cable inputs
S400 operation
±
0.315
ns
S100 operation
±
0.8
Receive input skew
Between TPA and TPB cable inputs
S200 operation
±
0.55
ns
Receive input skew
Between TPA and TPB cable inputs
S400 operation
±
0.5
ns
TA
Operating ambient temperature range
0
25
70
°
C
TJ#
Virtual junction temperature
0
25
115
°
C
† Applies to external inputs and bidirectional buffers without hysteresis
‡ Miscellaneous terminals are A03, B17, C15, C18, E05, E08, F19, H03, J01, J02, J03, J05, J06, J07, L02, L03, L05, M01, M02, M03, N01, N02,
N13, P12, P15, R02, R17, T01 (A_CCDx, A_CDx, A_CVSx, A_VSx, B_CCDx, B_CDx, B_CVSx, B_VSx, SD_DAT0, SD_DAT2, SD_DAT3,
SD_CMD, SD_CLK, SD_DAT1, SM_CLE, SC_CD, SC_OC, SC_PWR_CTRL, CLK_48, SDA, SCL, DATA, LATCH, TEST0, CNA, SUSPEND,
PHY_TEST_MA, and GRST terminals).
§ Applies to external output buffers
¶ For a node that does not source power, see Section 4.2.2.2 in IEEE Std 1394a−2000.
# These junction temperatures reflect simulation conditions. The customer is responsible for verifying junction temperature.
k
MFUNC(0:6) share the same specifications as the PCI terminals.