13.19 Power Management Control and Status Register

The power management control and status register implements the control and status of the Smart Card controller.
This register is not affected by the internally generated reset caused by the transition from the D3

hot

to D0 state. See

Table 13−12 for a complete description of the register contents.

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Name

Power management control and status

Type

RCU

R

R

R

R

R

R

RW

R

R

R

R

R

R

RW

RW

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Register:

Power management control and status

Offset:

48h

Type:

Read/Clear/Update, Read/Write, Read-only

Default:

0000h

Table 13−12. Power Management Control and Status Register Description

BIT

FIELD NAME

TYPE

DESCRIPTION

15 ‡

PME_STAT

RCU

PME status. This bit is set when the function would normally assert the PME signal independent of the
state of PME_EN bit. Writing a 1 to this bit clears it and causes the function to stop asserting a PME
(if enabled). Writing a 0 has no effect. This bit is initialized by GRST only when the PME_D3cold bit
is 1.

14−9

RSVD

R

Reserved. Bits 14−9 return 0s when read.

8 ‡

PME_EN

RW

PME enable. This bit is initialized by GRST only when PME_D3cold bit is 1.

7−2

RSVD

R

Reserved. Bits 7−2 return 0s when read.

1−0 ‡

DSTATE

RW

Device State: This bit field controls device power management state. Invalid state assignments are
ignored. (ex. Current state 10b

writing 01b. This is rejected and stays 10b. See the latest PCI Local

Bus Specification.) This bit field is initialized by GRST only when PME_D3cold bit is 1.

‡ One or more bits in this register are cleared only by the assertion of GRST.

13.20 Power Management Bridge Support Extension Register

The power management bridge support extension register provides extended power-management features not
applicable to the Smart Card controller; thus, it is read-only and returns 0 when read.

Bit

7

6

5

4

3

2

1

0

Name

Power management bridge support extension

Type

R

R

R

R

R

R

R

R

Default

0

0

0

0

0

0

0

0

Register:

Power management bridge support extension

Offset:

4Ah

Type:

Read-only

Default:

00h