36 asynchronous request filter low register – Texas Instruments Dual/Single Socket CardBus and UntraMedia Controller PCI7621 User Manual
Page 214
8−34
8.36 Asynchronous Request Filter Low Register
The asynchronous request filter low set/clear register enables asynchronous receive requests on a per-node basis,
and handles the lower node IDs. Other than filtering different node IDs, this register behaves identically to the
asynchronous request filter high register. See Table 8−28 for a complete description of the register contents.
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Name
Asynchronous request filter low
Type
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Name
Asynchronous request filter low
Type
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
RSC
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Register:
Asynchronous request filter low
Offset:
108h
set register
10Ch
clear register
Type:
Read/Set/Clear
Default:
0000 0000h
Table 8−28. Asynchronous Request Filter Low Register Description
BIT
FIELD NAME
TYPE
DESCRIPTION
31
asynReqResource31
RSC
If bit 31 is set to 1 for local bus node number 31, asynchronous requests received by the controller
from that node are accepted.
30
asynReqResource30
RSC
If bit 30 is set to 1 for local bus node number 30, asynchronous requests received by the controller
from that node are accepted.
29−2
asynReqResourcen
RSC
Bits 29 through 2 (asynReqResourcen, where n = 29, 28, 27,
…
, 2) follow the same pattern as
bits 31 and 30.
1
asynReqResource1
RSC
If bit 1 is set to 1 for local bus node number 1, asynchronous requests received by the controller
from that node are accepted.
0
asynReqResource0
RSC
If bit 0 is set to 1 for local bus node number 0, asynchronous requests received by the controller
from that node are accepted.