Basic Hardware and Function

27

1. System Configuration

1.6 Programmer port function


The interface of the T1-16S’s programmer port is RS-232C. Normally this port is
used to connect the programmer. However, this port can also be used for the
computer link function.

The computer link is a data communication function between computer or operator
interface unit and the T1-16S. The data in the T1-16S can be read and written by
creating simple communication program on the computer. The computer link protocol
of the T1-16S is published in “T1-16S User’s Manual

Communication Function

”.

Item

Specifications

Interface

Conforms to RS-232C

Transmission system

Half-duplex

Synchronization

Start-stop system (asynchronous)

Transmission speed

9600 bps (fixed)

Transmission distance

15 m max.

Framing

Start bit:

Data bits:

Parity:

Stop bit:

1 bit

8 bits (fixed)

Odd or none

1 bit (fixed)

Protocol

T-series computer link (ASCII)

Programmer (binary)

Transmission delay option

0 to 300 ms

By using the multi-drop adapter (CU111), multiple T1-16Ss can be connected on an
RS-485 line. The T-series PLC programming software (T-PDS) can also be used in
this configuration.

T1-16S

C
U

Operator Interface

Master Computer

RS-232C

RS-485 (1 km max.)

Max. 32 T1-16Ss

T1-16S

C
U

T1-16S

C
U

T1-16S