T1-16S User’s Manual

7. Instructions

FUN 186

ASC

ASCII conversion

Expression

Input

[ A ASC B ]

Output

Function

When the input is ON, this instruction converts the alphanumeric characters into the ASCII codes,
and stores them in the register table starting with B. (16 characters maximum)

Execution condition

Input

Operation

Output

OFF

No execution

OFF

ON

Execution

ON

Operand

Name

Device

Register

Constant Index

X

Y

R

S

T.

C. XW YW RW SW T

C

D

I

J

K

A Characters

B Start of

destination

Example

When R030 is ON, the characters ‘ABCDEFGHIJKLMN’ is converted into the ASCII codes, and
the result is stored in 8 registers starting with lower 8 bits (byte) of D0200 (D0200 to D0207).

High

Low

F 8

7 0

D0200 H42 (B)

H41 (A)

D0201 H44 (D)

H43 (C)

D0202 H46 (F)

H45 (E)

D0203 H48 (H)

H47 (G)

D0204 H4A (J)

H49 (I)

D0205 H4C (L)

H4B (K)

D0206 H4E (N)

H4D (M)

D0207

Note

Only the number of bytes converted are stored. The rest are not changed. In the above

example, 14 characters are converted into 14 bytes of ASCII code, and these ASCII codes are
stored in 7 registers (D0200 to D0206). The data of D0207 remains unchanged.

Previous data is remained