beautypg.com

Toshiba 6F3B0253 User Manual

Page 197

background image

6F3B0253

Basic Hardware and Function

195

7. Instructions

FUN 113

U

<=

Unsigned less than or equal

Expression

Input

[ A U

<=

B ]

Output

Function

When the input is ON, the data of A and the data of B are compared, and if A is less than or equal
to B, the output is turned ON.

Execution condition

Input

Operation

Output

OFF

No execution

OFF

ON

Execution

A

B

ON

A

>

B

OFF

Operand

Name

Device

Register

Constant Index

X

Y

R

S

T.

C. XW YW RW SW T

C

D

I

J

K

A Compared

data

B Reference

data

Example

When R00C is ON, the data of D0125 is compared with the constant data 35000, and if the
data of D0125 is less than or equal to 35000, R020 is turned ON.

If the data of D0125 is 35000, the comparison result is true. Consequently, R020 is turned ON.

D0125

35000

Constant 35000

R020 is ON

If the data of D0125 is 0, the comparison result is false. Consequently, R020 is turned OFF.

D0125

38000

>

Constant 35000

R020 is OFF

Note