4-24 Configuring Your Server

Option

Parameter

Description

Your Setting

Power on Delay
Time

[0] - 255

Specify the DC power on delay
time within the range between 0
and 255 seconds. The time
specified is valid when "Power On"
or "Last State" is specified for AC
LINK.

Platform Event
Filtering

Disabled
[Enabled]

This item becomes meaningless
when the notification feature of
EXPRESSSCOPE Engine is
enabled.

[ ]: Factory-set

The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."

Setting of AC LINK

System status before AC power off

Stay Off

Last State

Power On

Operating

Off

On

On

Aborting (DC power being off also)

Off

Off

On

Forced shutdown

Off

Off

On

* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.

IMPORTANT:

„

To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC Link] - [Power On].

„

If the server is connected to the UPS, set at least 10 seconds delay in
the power-on schedule.